Bug
Bug ID Number | BUG-000161332 |
---|---|
Submitted | September 11, 2023 |
Last Modified | October 8, 2024 |
Applies to | Portal for ArcGIS |
Version found | 11.1 |
Operating System | Windows Server |
Operating System Version | 2019 64 Bit |
Version Fixed | 11.1 |
Status | Fixed |
Installing the Portal for ArcGIS 11.1 Enterprise Sites Security Patch causes advanced 3D symbols to no longer display properly in the Scene Viewer. This defect is identified as BUG-000161332 and is present in the initial A version of the patch released on June 28, 2023 and a subsequent B version released on July 6, 2023. The most current C version of the patch released on December 12, 2023, does not cause this issue. Users who experienced the issue with the A and B version of this patch cannot resolve the problem by uninstalling the patch, nor by applying the most current C version of the patch. BUG-000161332 caused files provided by Portal for ArcGIS 11.1 Web Styles to be removed. To resolve the issue, a repair or reinstall of the Portal for ArcGIS 11.1 Web Styles is needed as outlined in the steps below.
The Portal for ArcGIS 11.1 Enterprise Sites Security Patch erroneously removes a file and a directory installed by Portal for ArcGIS 11.1 Web Styles that enables advanced 3D symbols in the Scene Viewer.
For users who were impacted by BUG-000161332, neither uninstalling the patch nor applying the most current C version of the patch will offer a resolution. Instead, follow these steps to ensure the affected file and directory are re-created:
Get help from ArcGIS experts
Download the Esri Support App