中文
漏洞编号 BUG-000126198
已提交 Oct 22, 2019
Modified Jun 02, 2021
严重性 Medium
应用于 Portal for ArcGIS
找到的版本 10.7.1
程序语言 N/A
服务器平台
客户端平台
数据库 N/A
区域设置 N/A
状态 Implemented
Learn more
修正版本 10.8.1
SP 修复 N/A

漏洞 BUG-000126198

摘要

The primary portal and the standby portal are no longer accessible after the pg_hba.conf entries are commented out.


附加信息

N/A


备用解决方案

1.On primary Portal, open the pg_hba.conf and uncomment out the entries (Ex. C:\arcgisportal\db\pg_hba.conf). See below:

 

# IPv4 local connections:

host  all       portaladmin       127.0.0.1/32      md5

host  replication   portaladmin       127.0.0.1/32      md5

# IPv6 local connections:

host  all       portaladmin       ::1/128         md5

host  replication   portaladmin       ::1/128         md5)

 

host gwdb portaladmin portalPrimary.domain.com md5

host gwdb portaladmin portalStandby.domain.com md5

 

host gwdb portaladmin 10.151.10.25 md5

host gwdb portaladmin 10.151.10.26 md5

 

2. Reload Portal for ArcGIS database with the following command, in an administrator command prompt.

  • cd C:\Program Files\ArcGIS\Portal\framework\runtime\pgsql\bin
  • pg_ctl.exe reload -D C:\arcgisportal\db

 

3. Stop and start Portal for ArcGIS' internal database.

  • pg_ctl.exe stop -D C:\arcgisportal\db
  • pg_ctl.exe start -D C:\arcgisportal\db

 

4. You should now be able to access the primary Portal for ArcGIS.

 

5. Repeat Steps 1 through 3 for the standby Portal for ArcGIS.