When the error "25: Stacked point features" is returned in a utility network, and the Terminal Path is set to null, the error "39: Point feature has invalid terminal configuration" is also returned. The errors cannot be resolved without first resolving error ID 25 by dropping and re-enabling the network topology.

ArcGIS Pro
漏洞 ID 编号 BUG-000164281
已提交January 11, 2024
上次修改时间February 7, 2024
适用范围ArcGIS Pro
找到的版本3.2
操作系统Windows OS
操作系统版本10.0 64 Bit
状态In Review

解决办法

To remove the error, replace the null Terminal Path with 'Default', drop the network topology, and re-enable it. Move the overlapping points responsible for error ID 25 to also remove error ID 39. 