When creating an Elevation Service of 32-Bit DEMs, the floating point values are not maintained within the Table of Contents.
上次发布: August 25, 2014ImageServer
漏洞 ID 编号
NIM041160
已提交
January 5, 2009
上次修改时间
June 5, 2024
适用范围
ImageServer
找到的版本
9.3
操作系统
Windows OS
操作系统版本
XP
状态
Will Not Be Addressed
开发团队已考虑过该问题或请求,并决定不会解决该问题。 问题的“其他信息”部分可能包含进一步说明。
附加信息
We apologize that we were unable to address this issue within the current product support cycle. If the issue continues to affect your work in a supported release, please contact Technical Support.
解决办法
Specify the floating point values within the layer properties under the symbology tab. Change the Strech type to Minimum-Maximum > Check on Edit High/Low Values > Modify the floating point values to be the correct values. This will only maintain the floating point values while the user operates within this session of ArcMap. Once the Service is added back into ArcMap at a later date the values will revert back to integer.