laptop and a wrench

漏洞

When an ArcGIS for Desktop installation is performed silently and the BLOCKADDINS parameter value is set to '3' (blocking installations of any add-ins not signed by Esri or installed from the administrator folder), the Address Coder toolbar with an .esriAddIn file cannot be installed when installing Esri Business Analyst Desktop 10.3.

上次发布: September 8, 2020 ArcGIS for Desktop
漏洞 ID 编号 BUG-000086406
已提交March 26, 2015
上次修改时间June 5, 2024
适用范围ArcGIS for Desktop
找到的版本10.3
操作系统Windows OS
操作系统版本7 64 Bit
状态Will Not Be Addressed

附加信息

We apologize that we were unable to address this issue within the current product support cycle. If the issue continues to affect your work in a supported release, please contact Technical Support.

解决办法

Copy the Address Coder Toolbar.esriAddIn file to the administrator folder. It is installed automatically the next time ArcGIS for Desktop is initialized. (Ignore the error given by the installer in the meantime as this workaround does not solve the error when the installation is performed silently.)

Alternatively, prior to executing an installation of Esri Business Analyst programmatically, the administrator can perform the following steps:

1. Set the system’s registry key to a value of 0, allowing the installation of all add-ins.

2. Perform the installation.

3. Change the registry key back to a value of 3 once the installation is completed.

This workaround avoids the error completely. This kind of logic needs to be integrated directly into the ESRI Business Analyst Desktop installer if add-ins are part of the install procedure.