The Utility Network downstream trace returns different results in ArcGIS Pro 2.7 compared to ArcGIS Pro 2.6.
上次发布: July 19, 2021ArcGIS Pro
漏洞 ID 编号
BUG-000137618
已提交
February 22, 2021
上次修改时间
June 5, 2024
适用范围
ArcGIS Pro
找到的版本
2.7.1
操作系统
Windows OS
操作系统版本
N/A
状态
Known Limit
经开发团队审核,已确定此问题与不受 Esri 控制的软件的已知限制有关。 问题的“其他信息”部分可能包含进一步说明。
附加信息
The Utility Network does not have flow direction in it as it currently sits. Thus, when hitting a loop in the data (between starting location and the Sink), the user must check the check box to Allow Indeterminate Flow for the trace to success and make it all the way from the starting location to the sink. However, the entire loop is selected because it is indeterminate.
Another option is to put devices with terminals at each of the intersections. 1 in, 2 out in some cases, and 2 in, 1 out in other cases where it alerts the system exactly which way things can traverse through those devices and the 'flow' is correctly calculated. If you have a 3 in 1 out or 1 in 3 out of the situation, use ArcGIS Pro 2.8 to allow better configuration of those terminals and their paths through the device. The result shown in ArcGIS Pro 2.6 can be seen as incorrect because that loop is not selected. This can be resolved using devices with terminals, and this is fixed in ArcGIS Pro 2.8. The other option is to look at the Trace Network.