laptop and a wrench

漏洞

The Gas Utility Network Configuration of the Cathodic network trace fails to pass through a cathodically traceable regulator device.

上次发布: July 11, 2022 ArcGIS Pro
漏洞 ID 编号 BUG-000149307
已提交May 17, 2022
上次修改时间June 5, 2024
适用范围ArcGIS Pro
找到的版本2.6.8
操作系统Windows OS
操作系统版本10.0 64 Bit
状态Known Limit

附加信息

Because the cathodic protection system is using the same features and connectivity as the water and gas commodity, it is limited by things like terminal configurations, associations, and terminal directions. The most common impact is when the test lead for a cathodic protection system is 'downstream' from a directional device like a pressure reducing valve resulting in the pressure reducing valve stopping the cathodic protection system.

解决办法

Update the model to create a bonding junction on one of the sides of the dead zone and bridge the gap using a bonding wire.

重现步骤

漏洞 ID: BUG-000149307

软件:

  • ArcGIS Pro

当漏洞状态发生变化时获得通知

下载 Esri 支持应用程序

发现关于本主题的更多内容

获取来自 ArcGIS 专家的帮助

联系技术支持部门

下载 Esri 支持应用程序

转至下载选项