The Fill (Spatial Analyst) tool has a 2 meter range difference when comparing outputs from ArcGIS Desktop 10.4 to ArcGIS Desktop 10.6.1 with a z-limit of 1 meter.
上次发布: August 21, 2019ArcGIS Pro
漏洞 ID 编号
BUG-000124624
已提交
August 19, 2019
上次修改时间
June 5, 2024
适用范围
ArcGIS Pro
找到的版本
2.3.2
状态
Will Not Be Addressed
开发团队已考虑过该问题或请求,并决定不会解决该问题。 问题的“其他信息”部分可能包含进一步说明。
附加信息
The new output from the Fill tool with the z-limit starts at ArcGIS Desktop 10.5.1 is the correct expected behavior following a bug fix.
According to the Fill tool help page, "The z-limit specifies the maximum difference allowed between the depth of a sink and the pour point and determines which sinks will be filled and which will remain untouched."
To check if the z-limit is being honored, run the Fill tool without the z-limit and calculate the difference to the input raster using the Minus tool. The output surface from the Minus tool represents all sink regions in the terrain that can be filled without the z-limit restrictions and the corresponding depths at each cell. Any sink regions in this surface that exceed a specific z-limit value in depth at any cell should be ignoredwhen the filling operation is run with such a z-limit.