The Fill (Spatial Analyst) tool has a 2 meter range difference when comparing outputs from ArcGIS Desktop 10.4 to ArcGIS Desktop 10.6.1 with a z-limit of 1 meter.

上次发布: August 21, 2019 ArcGIS Pro
漏洞 ID 编号 BUG-000124624
已提交August 19, 2019
上次修改时间June 5, 2024
适用范围ArcGIS Pro
找到的版本2.3.2
状态Will Not Be Addressed

附加信息

The new output from the Fill tool with the z-limit starts at ArcGIS Desktop 10.5.1 is the correct expected behavior following a bug fix. According to the Fill tool help page, "The z-limit specifies the maximum difference allowed between the depth of a sink and the pour point and determines which sinks will be filled and which will remain untouched." To check if the z-limit is being honored, run the Fill tool without the z-limit and calculate the difference to the input raster using the Minus tool. The output surface from the Minus tool represents all sink regions in the terrain that can be filled without the z-limit restrictions and the corresponding depths at each cell. Any sink regions in this surface that exceed a specific z-limit value in depth at any cell should be ignoredwhen the filling operation is run with such a z-limit.