,8, your server will be removed!'" This is working as designed. The failed counter was removed as expected. Simply restarting t"/>
获取应用程序中的漏洞更新
URL 已复制共享 URL
漏洞
The ArcGIS Monitor Server does not show the System Contour, If the System Contour is re added after being dropped by ArcGIS Monitor Administrator due to its inability to connect within fixed attempts.
上次发布: May 15, 2018ArcGIS Monitor
漏洞 ID 编号
BUG-000113723
已提交
May 4, 2018
上次修改时间
October 31, 2025
适用范围
ArcGIS Monitor
找到的版本
10.6
操作系统
Windows OS
操作系统版本
2012 R2
状态
Known Limit
经开发团队审核,已确定此问题与不受 Esri 控制的软件的已知限制有关。 问题的“其他信息”部分可能包含进一步说明。
附加信息
As the log entry indicates, when the System collection reaches "Failed Attempts:,8" the logic follows, "If Failed Attemts >,8, your server will be removed!'" This is working as designed. The failed counter was removed as expected. Simply restarting the ArcGIS Monitor Service will reset the failed attempts to zero and the existing System counter can continue collecting. If the ArcGIS Monitor Service was restarted, there's no need to create a new connection or re-add the counter.
In ArcGIS Monitor 10.6.1, the following design change will be made: As long as the ArcGIS Monitor Service is running, data collection will automatically be attempted at the sample interval. If an items fails to collect, it will continue to be listed as monitoring failure until the data collection is successful at the sample interval.
解决办法
Creating a new connection and re adding the same System Contour resolves the issue.