laptop and a wrench

漏洞

Several projected coordinate systems covering South Africa cannot be found in ArcGIS Pro using the EPSG code.

ArcGIS Pro
漏洞 ID 编号 BUG-000165201
已提交February 17, 2024
上次修改时间June 5, 2024
适用范围ArcGIS Pro
找到的版本3.2.1
操作系统Windows OS
操作系统版本11.0 64 bit
状态Known Limit

附加信息

The 102470-102479 definitions emulates the EPSG 22275/77/79/81/83/85/87/89/91/93 definitions by setting the scale factor to -1, resulting in dismissed coordinate signs. Hence, data allowed that are natively relative to the westing-southing axes directions is not supported currently by ArcGIS, resulting in definitions use ESRI WKIDs instead of EPSG. The EPSG 2046-2054 definitions also have westing-southing axes directions and are not supported. The names of that set of EPSG coordinate reference systems are Hartebeesthoek94 / LOxx in EPSG and do not include (E-N) in the names. The Esri 103888, 102562-69 definitions are not equivalent to the EPSG 2046-2054 definitions. These are added upon request with easting-northing axes directions.