laptop and a wrench

漏洞

Location Referencing ribbon tools do not recognize the linear referencing system (LRS) layers after changing the data sources from one service on one Portal to another service on a different Portal.

上次发布: August 13, 2020 Pipeline Referencing – Pro
漏洞 ID 编号 BUG-000132825
已提交August 4, 2020
上次修改时间July 13, 2025
适用范围Pipeline Referencing – Pro
找到的版本2.6
操作系统Windows OS
操作系统版本10.0 64 Bit
修正版本2.7
状态Fixed

解决办法

  1. Create a fresh ArcGIS Pro project, and add data from the new Portal environment.
  2. Use Save To Layer File geoprocessing tool to create layer files from the old ArcGIS Pro project.
  3. Use Apply Symbology From Layer geoprocessing tool to import layer symbology to feature layers in the new ArcGIS Pro project.

For multiple feature layers, automate the process using ModelBuilder or Script.