Incorrect elevation data when using Trimble R2 between Collector for ArcGIS (Aurora) and Collector for ArcGIS (Classic).
上次发布: January 21, 2020Collector Classic for ArcGIS (iOS)
漏洞 ID 编号
BUG-000127592
已提交
December 26, 2019
上次修改时间
June 5, 2024
适用范围
Collector Classic for ArcGIS (iOS)
找到的版本
19.0.2
操作系统
Apple iOS
操作系统版本
12.0x
状态
Will Not Be Addressed
开发团队已考虑过该问题或请求,并决定不会解决该问题。 问题的“其他信息”部分可能包含进一步说明。
附加信息
When working with Trimble receivers to capture elevations in Collector for ArcGIS (Aurora) or Collector for ArcGIS (Classic), specifying a value for the Antenna Height, the inclusion of the Antenna Phase Center (APC) measurement for the receiver depends on which version of Collector for ArcGIS is being used:
Collector for ArcGIS (Aurora) - The APC measurement is included by default when working with Trimble receivers. Therefore, it does not need to be added to the Antenna Height value and only requires the height of the range pole.
Collector for ArcGIS (Classic) - The APC measurement is not included by default, and needs to be included with the Antenna Height and the range pole height.
Therefore, the differences in the elevation between Collector for ArcGIS (Classic) and Collector for ArcGIS (Aurora) is likely due to the APC measurement being included in Collector for ArcGIS (Aurora) when it is not required.
A similar explanation was provided here - https://community.esri.com/ideas/17804