laptop and a wrench

漏洞

Connectivity rules are not recognized after un-assigning a user-defined terminal configuration in a utility network.

ArcGIS Pro
漏洞 ID 编号 BUG-000167417
已提交May 13, 2024
上次修改时间February 14, 2025
适用范围ArcGIS Pro
找到的版本3.2.2
操作系统Windows OS
操作系统版本10.0 64 Bit
状态As Designed

附加信息

The invalid connectivity error is expected in this scenario as the existing connectivity rules reference terminal connections that no longer exist. Running Set Terminal Configuration does not impact the rule set, as a result the J-E rules that references specific terminals are no longer valid after modifying the terminal configuration. If the terminal configuration is altered, specify a single terminal configuration. Existing rules must be deleted, and new ones are created that does not reference the terminals.

解决办法

 Use the Add Rule tool to create new junction-edge connectivity rules. Use the Delete Rule tool to remove invalid rules that reference the removed terminals.