laptop and a wrench

漏洞

Communications Utility Network Foundation Solution is encountering the "Error 001797: No valid subnetwork controllers found" error while following the task to perform the 'Customer to upstream Switch' trace.

ArcGIS Pro
漏洞 ID 编号 BUG-000167050
已提交April 26, 2024
上次修改时间July 9, 2024
适用范围ArcGIS Pro
找到的版本3.2.2
操作系统Windows OS
操作系统版本10.0 64 Bit
状态In Product Plan

附加信息

The task calls the models in Communications Trace toolbox. These models leverage the Utility Network Trace GP Tool. The Starting Points input must be mapped to Trace Features\Starting Points but is incorrectly pointing to Wire Cabinets. Adjust the Starting Points input and the task and model succeeds.

解决办法

In the Communications Traces toolbox, open each model and adjust the Starting Points input to point to Trace Features\Starting Points.

重现步骤

漏洞 ID: BUG-000167050

软件:

  • ArcGIS Pro

当漏洞状态发生变化时获得通知

下载 Esri 支持应用程序

发现关于本主题的更多内容

获取来自 ArcGIS 专家的帮助

联系技术支持部门

下载 Esri 支持应用程序

转至下载选项