laptop and a wrench

漏洞

ArcGIS Pro crashes when adding a new calibration point.

上次发布: April 8, 2022 Pipeline Referencing – Pro
漏洞 ID 编号 BUG-000148278
已提交April 5, 2022
上次修改时间June 5, 2024
适用范围Pipeline Referencing – Pro
找到的版本2.7
操作系统Windows OS
操作系统版本10.0 64 Bit
状态Known Limit

附加信息

The issue is not reproducible in ArcGIS Pro 2.9. It is caused by curve segments being present in the data along with the wrong coded value domain being mapped for the field NetworkID in the Calibration Point feature class and Centerline Sequence table.

解决办法

Map the domain dLRSNetworks for the field, and densify the curve feature for the tool to execute correctly.

重现步骤

漏洞 ID: BUG-000148278

软件:

  • Pipeline Referencing – Pro

当漏洞状态发生变化时获得通知

下载 Esri 支持应用程序

发现关于本主题的更多内容

获取来自 ArcGIS 专家的帮助

联系技术支持部门

下载 Esri 支持应用程序

转至下载选项