漏洞

Adding a transformer to a conductor line disconnects downstream features from the subnetwork.

上次发布: October 11, 2022 ArcGIS Pro
漏洞 ID 编号 BUG-000152483
已提交September 21, 2022
上次修改时间June 5, 2024
适用范围ArcGIS Pro
找到的版本2.9.4
操作系统Windows OS
操作系统版本10.0 64 Bit
状态As Designed

附加信息

The Connection Point::Overhead Solid Connection placed midspan along the Medium Voltage Conductor does not have Lifecycle Status configured as 'In Service' which makes this a condition barrier as defined in the subnetwork definition for the tier. Updating the Lifecycle Status enables the subnetwork trace to complete and displays the expected Phases Energized on downstream features after running the Update Subnetwork.

解决办法

Configure the Lifecycle Status of the newly placed Connection Point so that it is not a barrier for the subnetwork trace.