漏洞 ID 编号 |
BUG-000161864 |
已提交 | October 4, 2023 |
上次修改时间 | June 5, 2024 |
适用范围 | ArcGIS GIS Server |
找到的版本 | 10.9.1 |
操作系统 | Windows Server |
操作系统版本 | 2019 64 Bit |
状态 | Duplicate
此问题与现有问题重复。 有关详细信息,请参阅问题的“其他信息”部分。 与重复问题关联的客户将自动附加到未解决的问题。
|
附加信息
This issue is no longer reproducible with ArcGIS Server 10.9.1 Utility Network and Data Management Patch 6. Refer to the documentation: https://support.esri.com/en-us/patches-updates/2023/arcgis-server-10-9-1-utility-network-and-data-management-patch-6.
解决办法
Workaround 1:
- Use an upstream trace with the same filter barrier of isolation.
- Set the trace output to only output Device > Controllable Value > Stop – Sluice. This must be done in multiple locations to select all the features.
Workaround 2: Upgrade to ArcGIS Pro 3.1.3 (or later) if working with a file or mobile geodatabase. Use ArcGIS Server 10.9.1 Utility Network and Data Management Patch 6 or alter if working with an enterprise geodatabase.
重现步骤