laptop and a wrench

漏洞

A utility network isolation trace does not select isolating devices upstream from the starting point.

ArcGIS GIS Server
漏洞 ID 编号 BUG-000161864
已提交October 4, 2023
上次修改时间June 5, 2024
适用范围ArcGIS GIS Server
找到的版本10.9.1
操作系统Windows Server
操作系统版本2019 64 Bit
状态Duplicate

附加信息

This issue is no longer reproducible with ArcGIS Server 10.9.1 Utility Network and Data Management Patch 6. Refer to the documentation: https://support.esri.com/en-us/patches-updates/2023/arcgis-server-10-9-1-utility-network-and-data-management-patch-6.

解决办法

Workaround 1:

  1. Use an upstream trace with the same filter barrier of isolation.
  2. Set the trace output to only output Device > Controllable Value > Stop – Sluice. This must be done in multiple locations to select all the features.

Workaround 2: Upgrade to ArcGIS Pro 3.1.3 (or later) if working with a file or mobile geodatabase. Use ArcGIS Server 10.9.1 Utility Network and Data Management Patch 6 or alter if working with an enterprise geodatabase.