laptop and a wrench

Erro

When the error "25: Stacked point features" is returned in a utility network, and the Terminal Path is set to null, the error "39: Point feature has invalid terminal configuration" is also returned. The errors cannot be resolved without first resolving error ID 25 by dropping and re-enabling the network topology.

ArcGIS Pro
Número de ID do Erro BUG-000164281
EnviadoJanuary 11, 2024
Última ModificaçãoFebruary 7, 2024
Aplica-se àArcGIS Pro
Versão encontrada3.2
Sistema OperacionalWindows OS
Versão do Sistema Operacional10.0 64 Bit
StatusIn Review

Solução Provisória

To remove the error, replace the null Terminal Path with 'Default', drop the network topology, and re-enable it. Move the overlapping points responsible for error ID 25 to also remove error ID 39. 

Etapas para Reproduzir

ID do Erro: BUG-000164281

Software:

  • ArcGIS Pro

Seja notificado quando o status de um erro mudar

Baixe o Aplicativo de Suporte da Esri

Descubra mais sobre este tema

Obtenha ajuda de especialistas do ArcGIS

Entre em contato com Suporte Técnico

Baixe o Aplicativo de Suporte da Esri

Ir para as opções de download