Erro

When moving or creating point features to a line in a linear referencing system (LRS) or a utility network (UN), the error message "Error: Unable to complete operation. The modified centerline geometry will result in an uncalibrated or non-monotonic route." is returned.

ArcGIS Pro
Número de ID do Erro BUG-000164825
EnviadoFebruary 2, 2024
Última ModificaçãoJune 5, 2024
Aplica-se àArcGIS Pro
Versão encontrada2.9.11
Sistema OperacionalWindows OS
Versão do Sistema Operacional10.0 64 Bit
Versão Fixa3.3
StatusWill Not Be Addressed

Informações Adicionais

This is due to data issues. The centerlines associated with the route with OID 4375 are not coincident in 3D (the Z values between the centerlines are different). When the junction point is added, a cartographic realignment is triggered and fails due to the Z values not being connected.

Solução Provisória

Snapping an Unknown/Unknown Asset Group Asset Type point to the line works successfully, and then changing this to Weld/Weld. The Snap geoprocessing tool also allows snapping the Weld/Weld or other points to the line.