laptop and a wrench

Erro

When connected as 'sde' or 'dbo', using the sdeversion -o alter to change version permissions for any version other than the sde.default/dbo.default version returns a Version not found (-126) error.

Última Publicação: April 19, 2017 ArcSDE/Enterprise Geodatabase
Número de ID do Erro NIM078732
EnviadoMarch 1, 2012
Última ModificaçãoApril 2, 2025
Aplica-se àArcSDE/Enterprise Geodatabase
Versão encontrada10.0
Sistema OperacionalWindows OS
Versão do Sistema Operacional2003
StatusKnown Limit

Informações Adicionais

This is by design. Error message improvement code was added when 64BBITID code changes were implemented in ArcGIS 10.3.

Solução Provisória

In addition to changing version permissions for all versions via ArcCatalog when connected as the SDE user, there are three additional workarounds for this issue outside of the SDE command line.1. Within the Alter Version geoprocessing tool, when connected as the SDE or DBO user, even though other versions are not listed, manually type in the version name and set the permissions.2. Build a model using the Alter Version tool. Within the model, specify the connection, version, and permissions. Click OK to execute.3. Convert the model into a Python script and execute. This allows the process to be scripted.

Etapas para Reproduzir

ID do Erro: NIM078732

Software:

  • ArcSDE/Enterprise Geodatabase

Seja notificado quando o status de um erro mudar

Baixe o Aplicativo de Suporte da Esri

Descubra mais sobre este tema

Obtenha ajuda de especialistas do ArcGIS

Entre em contato com Suporte Técnico

Baixe o Aplicativo de Suporte da Esri

Ir para as opções de download