laptop and a wrench

Erro

Upstream traces return incorrect or misleading results

ArcGIS Pro
Número de ID do Erro BUG-000172481
EnviadoNovember 21, 2024
Última ModificaçãoJanuary 5, 2025
Aplica-se àArcGIS Pro
Versão encontrada3.3
Sistema OperacionalWindows OS
Versão do Sistema Operacional10.0 64 Bit
StatusAs Designed

Informações Adicionais

When running an upstream trace, if loops are encountered upstream from the starting point, these will be pulled into the result when Allow Indeterminate Flow is checked. In the provided scenario, the upstream trace encounters a line end which participates in junction junction connectivity associations with 3 fuse devices and another riser, creating a loop. Because Allow Indeterminate Flow is checked (enabled), the features within the loop are returned with the result, because we have no way to determine if the features are upstream or downstream of the starting point. Unchecking (disabling) Allow Indeterminate Flow with the trace returns the expected result and excludes the features from the upstream trace result.

Solução Provisória

Uncheck (disable) Allow Indeterminate Flow when running the upstream trace.