laptop and a wrench

Erro

Two way replica for attachments throwing "Synchronize Replica Failed The field is not nullable. [REL_GLOBALID]" error message when the parent feature of the attachment being synchronized is in the Adds table of the destination geodatabase.

ArcGIS Pro
Número de ID do Erro BUG-000119648
EnviadoJanuary 28, 2019
Última ModificaçãoMay 9, 2025
Aplica-se àArcGIS Pro
Versão encontrada3.2.2
Sistema OperacionalWindows OS
Versão do Sistema Operacional10.0 64 Bit
StatusWill Not Be Addressed

Informações Adicionais

The steps to reproduce is the wrong workflow. The recommended workflow is to include all related data in a single replica instead of separating the feature class and attachment table into two replicas.

Solução Provisória

Workaround 1:

Before synchronizing the attachments' replica, compress destination geodatabase and verify that all the parent features of the attachments being synchronized reside in the Base tables.

Workaround 2:

Create two different one way replicas for the attachments table: one from Parent to Child and another from Child to Parent.

Etapas para Reproduzir

ID do Erro: BUG-000119648