laptop and a wrench

Erro

Tracing connected features in a Utility Network from a barrier with two terminals does not traverse the opposite terminal.

ArcGIS Pro
Número de ID do Erro BUG-000165667
EnviadoMarch 6, 2024
Última ModificaçãoJune 5, 2024
Aplica-se àArcGIS Pro
Versão encontrada3.2.2
Sistema OperacionalWindows OS
Versão do Sistema Operacional10.0 64 Bit
StatusAs Designed

Informações Adicionais

In this scenario, a Condition barrier is configured for both the IN and OUT terminals (Asset Group is equal to Indeterminate) on the device, whereas a Starting point is only present on the IN terminal. Ignore Starting Points at Barriers is honored properly in this case but does not apply to the OUT terminal which also has a barrier present. This is what led to the trace result reported.

Solução Provisória

Place a second starting point on the other terminal (so that both the IN and OUT terminals have starting points) and run the trace again with the Ignore Barriers at Starting Points parameter checked.

Etapas para Reproduzir

ID do Erro: BUG-000165667

Software:

  • ArcGIS Pro

Seja notificado quando o status de um erro mudar

Baixe o Aplicativo de Suporte da Esri

Descubra mais sobre este tema

Obtenha ajuda de especialistas do ArcGIS

Entre em contato com Suporte Técnico

Baixe o Aplicativo de Suporte da Esri

Ir para as opções de download