laptop and a wrench

Erro

The Update Subnetwork tool fails and returns the error message, "ERROR 160319: Error stopping an edit session with save edits" and only succeeds after restarting ArcGIS Pro.

Última Publicação: January 11, 2023 ArcGIS Pro
Número de ID do Erro BUG-000151971
EnviadoAugust 30, 2022
Última ModificaçãoJune 13, 2025
Aplica-se àArcGIS Pro
Versão encontrada2.9.3
Sistema OperacionalWindows OS
Versão do Sistema Operacional10.0 64 Bit
Versão Fixa3.1, 2.9.7
StatusFixed

Informações Adicionais

This issue is addressed in ArcGIS Pro 3.1 and 2.9.7. Running an update on all subnetworks with continuous failure after enabling the network topology can sometimes fail on a file geodatabase and return the error message, "ERROR 160319: Error stopping an edit session with save edits."

Solução Provisória

One of the file geodatabase indexes was corrupt, causing the tool to fail. A fix is to be made in ArcGIS Pro 3.1. For ArcGIS Pro 2.9.x, the workaround is as follows:

  1. Close ArcGIS Pro.
  2. Delete the a0000001a.FDO_GLOBALID.atx file using the file explorer.
  3. Restart ArcGIS Pro and run the tool.

Etapas para Reproduzir

ID do Erro: BUG-000151971

Software:

  • ArcGIS Pro

Seja notificado quando o status de um erro mudar

Baixe o Aplicativo de Suporte da Esri

Descubra mais sobre este tema

Obtenha ajuda de especialistas do ArcGIS

Entre em contato com Suporte Técnico

Baixe o Aplicativo de Suporte da Esri

Ir para as opções de download