laptop and a wrench

Erro

The Feature To Line error message, "ERROR 160196: Invalid Topology" is returned when running output data from the Production Mapping models.

Última Publicação: August 23, 2022 ArcGIS Pro
Número de ID do Erro BUG-000151241
EnviadoAugust 2, 2022
Última ModificaçãoJune 5, 2025
Aplica-se àArcGIS Pro
Versão encontrada3.0
Sistema OperacionalWindows OS
Versão do Sistema Operacional10.0 64 Bit
Versão FixaArcGIS Pro 3.1
StatusFixed

Informações Adicionais

The unexpected, misleading error message is caused by a bug in the processing. This error should not occur once the bug is fixed. It is not necessary to modify information about the error messages at this time.

Solução Provisória

Workarounds to avoid the error if M Values are not needed in the output:

  • Recreate the spatial reference, accepting all defaults and use this new feature class for analysis. Refer to https://www.esri.com/arcgis-blog/products/arcgis-pro/analytics/geoprocessing-resolution-tolerance-and-hair/ which gives exact steps to recreate the spatial reference.
  • Set the M Domain in the geoprocessing environment to a larger range when running the tool. Suggested mMin= -1000 ; mMax 1000.

Etapas para Reproduzir