laptop and a wrench

Erro

The Append Routes geoprocessing tool fails and returns the following error, "160145: The field is not nullable.[ASSETTYPE]."

Última Publicação: November 6, 2020 Pipeline Referencing – Pro
Número de ID do Erro BUG-000135023
EnviadoOctober 29, 2020
Última ModificaçãoJune 5, 2024
Aplica-se àPipeline Referencing – Pro
Versão encontrada2.6.2
Sistema OperacionalWindows OS
Versão do Sistema Operacional10.0 64 Bit
Versão Fixa3.0
StatusFixed

Solução Provisória

  1. Use 'Append' to load PipelineLine.
  2. Use 'Append' to load LRSnetwork.
  3. Author a script to populate the Centerline_Sequence table. The table holds the cardinality or relationship between PipelineLine: LRSnetwork. Reference: LRS data model—ArcGIS Pro | Documentation 
  4. Generate Calibration Points or Append Calibration Points.
  5. Finally, use 'Generate Routes' to sync up the LRS components.