Modifying the horizontal coordinate system first within the 'Display XY Data' pane returns an error if a Z field is chosen from the table.

Última Publicação: September 3, 2020 ArcGIS Pro
Número de ID do Erro BUG-000132991
EnviadoAugust 11, 2020
Última ModificaçãoJune 5, 2024
Aplica-se àArcGIS Pro
Versão encontrada2.6
Sistema OperacionalWindows OS
Versão do Sistema Operacional10.0 64 Bit
StatusWill Not Be Addressed

Informações Adicionais

The error in the coordinate system dialog is necessary to prevent incompatible x,y and z coordinate systems. If a vertical coordinate system that does not have the same WGS_1984 datum as the pre-selected x,y coordinate system is selected, the same error is returned (it works both ways). Regarding the second point, geoprocessing tool parameters do not offer a 'None' option, this is accomplished by clearing the text.

Solução Provisória

  • Change the vertical coordinate system first.
  • Add a Z field after the horizontal coordinate system is selected.

Etapas para Reproduzir