Map projection for Lambert azimuthal equal-area is not available in ArcGIS Pro.

ArcGIS Pro
Número de ID do Erro BUG-000166421
EnviadoApril 2, 2024
Última ModificaçãoJune 5, 2024
Aplica-se àArcGIS Pro
Versão encontrada3.2.2
Sistema OperacionalWindows OS
Versão do Sistema Operacional11.0
StatusAs Designed

Informações Adicionais

The user is mixing up projection and Projected Coordinate System (PCS) objects. A projection or map projection object is the name of the algorithm that is used to flatten the earth model into a flat plane. All 43xxx Well-Known IDs (WKID) are map projections. A projected coordinate system uses a wider range of Well-Known ID (WKID) numbers but does not use the 43xxx range. The ranges or 53xxx and 54xxx are projected coordinate systems that sometimes include the projection name in the PCS name. In the projected_coordinate_systems.pdf file, Table 2 lists all projected coordinate systems while Table 3 lists all projection algorithms.

Solução Provisória

For Lambert azimuthal equal area-based Projected Coordinate System (PCS), create a custom/new projected coordinate system (PCS). There are not many projected coordinate systems that use the Lambert azimuthal equal area projection.

Etapas para Reproduzir

ID do Erro: BUG-000166421