ITopologicalOperator.Buffer ArcGIS VB.Net ArcObjects does not handle specific buffer distances when the Projected Coordinate System is "South_America_Albers_Equal_Area_Conic".

Última Publicação: August 25, 2014 ArcGIS for Desktop
Número de ID do Erro NIM069814
EnviadoJune 21, 2011
Última ModificaçãoJune 5, 2024
Aplica-se àArcGIS for Desktop
Versão encontrada10.1
Idioma do programaVB.Net
Sistema OperacionalWindows OS
Versão do Sistema Operacional7 64 Bit
StatusNon-Reproducible

Informações Adicionais

No Public Explanation

Solução Provisória

Redefine the coordinate system of the geometry : Dim pSpatialRefFact As ISpatialReferenceFactory2 = New SpatialReferenceEnvironment Dim pProjection As IProjectedCoordinateSystem = pSpatialRefFact.CreateProjectedCoordinateSystem(102033) 'esriSRProjCS_SAD1969S_AmericaAlbers ' Set the pPolygon to the feature which will generate error pErrorPolygon = pErrorFeature.ShapeCopy ' Redifine the projection pErrorPolygon.Project(pProjection) pTopoOp = pErrorPolygon pErrorBuffer = pTopoOp.Buffer(17000)

Etapas para Reproduzir

ID do Erro: NIM069814