laptop and a wrench

Erro

GeoEvent's "Watch Folder for New CSV Files" input connector is unable to parse a plus sign (+) as a Double value, even if it is within quotes.

Última Publicação: August 14, 2018 ArcGIS GeoEvent Server
Número de ID do Erro BUG-000113754
EnviadoMay 4, 2018
Última ModificaçãoJuly 28, 2020
Aplica-se àArcGIS GeoEvent Server
Versão encontrada10.5.1
StatusIn Product Plan

Solução Provisória

Remove the plus sign (+) from the data.ORUse regular expressions (in the Field Calculator) to trim the optional (+) from the received data and then construct a JSON String representation of a geometry which can be cast to a Geometry (with a second Field Calculator and a Field Mapper).ORUse TEXT adapter to ingest all data fields as String and output via a Push JSON to an External Website outbound connector and re-ingest the data as JSON using the more flexible adapter (doubles the event load on the message bus).