laptop and a wrench

Erro

After installing ArcGIS Server 10.8.1 Utility Network Patch 6, the Validate Network Topology tool returns the message, "ERROR 002981: Value exceeds valid range of column".

Última Publicação: March 3, 2022 ArcGIS Utility Network
Número de ID do Erro BUG-000147284
EnviadoMarch 2, 2022
Última ModificaçãoJanuary 26, 2026
Aplica-se àArcGIS Utility Network
Versão encontrada4
Sistema OperacionalWindows OS
Versão do Sistema Operacional10.0
StatusNon-Reproducible

Informações Adicionais

The last reproducible case of this failure occurred in Utility Network patches for ArcGIS Enterprise 10.8.1. As of the 10.9.1 release, this failure is no longer encountered. ArcGIS Enterprise 10.8.1 is no longer supported. Move to a supported release if encountering this failure.

Solução Provisória

  • When network topology validation fails, disable and re-enable network topology to get the Validate Network Topology tool to run successfully.
  • Remove ArcGIS Server 10.8.1 Utility Network Patch 6 and install ArcGIS Server 10.8.1 Utility Network Patch 5B.

Etapas para Reproduzir

ID do Erro: BUG-000147284

Software:

  • ArcGIS Utility Network

Seja notificado quando o status de um erro mudar