Adding a transformer to a conductor line disconnects downstream features from the subnetwork.

Última Publicação: October 11, 2022 ArcGIS Pro
Número de ID do Erro BUG-000152483
EnviadoSeptember 21, 2022
Última ModificaçãoJune 5, 2024
Aplica-se àArcGIS Pro
Versão encontrada2.9.4
Sistema OperacionalWindows OS
Versão do Sistema Operacional10.0 64 Bit
StatusAs Designed

Informações Adicionais

The Connection Point::Overhead Solid Connection placed midspan along the Medium Voltage Conductor does not have Lifecycle Status configured as 'In Service' which makes this a condition barrier as defined in the subnetwork definition for the tier. Updating the Lifecycle Status enables the subnetwork trace to complete and displays the expected Phases Energized on downstream features after running the Update Subnetwork.

Solução Provisória

Configure the Lifecycle Status of the newly placed Connection Point so that it is not a barrier for the subnetwork trace.