laptop and a wrench

Erro

3-tier connection from ArcCatalog to native 64-bit SDE hangs in a Windows 2003/2008 64-bit server environment.

Última Publicação: August 25, 2014 No Product Found
Número de ID do Erro NIM048382
EnviadoSeptember 21, 2009
Última ModificaçãoJune 5, 2024
Aplica-se àNo Product Found
Versão encontrada10.0
Versão FixaN/A
StatusFixed

Solução Provisória

1. Open CMD prompt2. Type set SDEFORCEXDR=13. Type in same CMD windows "C:\Program Files (x86)\ArcGIS\Bin\ArcCatalog.exe" to open ArcCatalog4. Create an sde database connection without fully qualifying the server nameRESULTS: Connection will be successful.b) Also setting SDEFORCEXDR=0 also resolved the issue.c) Another workaround was to provide fully qualified domain name with server name or IP Address in the Server column in Spatial Database Connection.

Etapas para Reproduzir

ID do Erro: NIM048382