When unchecking and rechecking the Business Analyst capability in the Service Properties of a map service using ArcGIS Server Manager, the configuration tag (<MainConfigPath>) is getting erased in the map configuration file, and the service will not start. Error message is "Unable to Start service. Error (Configuration DefaultMap.MapServer cannot be started. Server Object instance creation failed on machine." The service starts if the Business Analyst capability is unchecked.

最後に公開された状態: August 25, 2014 No Product Found
不具合 ID 番号 NIM063453
送信されましたDecember 9, 2010
最終更新日April 2, 2025
適用対象No Product Found
見つかったバージョン10.0
ステータスWill Not Be Addressed

参考情報

No Public Explanation

対処法

The workaround is to manually add the missing tag (<MainConfigPath>) to the map configuration file and restart the map service in ArcGIS Server Manager. Also, as long as the Administration component of Business Analyst server is run, in ArcCatalog, open the service properties, click on Capabilities tab, click on Business Analyst capability, under Properties, manually add the configuration file.