laptop and a wrench

不具合

When moving or creating point features to a line in a linear referencing system (LRS) or a utility network (UN), the error message "Error: Unable to complete operation. The modified centerline geometry will result in an uncalibrated or non-monotonic route." is returned.

ArcGIS Pro
不具合 ID 番号 BUG-000164825
送信されましたFebruary 2, 2024
最終更新日June 5, 2024
適用対象ArcGIS Pro
見つかったバージョン2.9.11
オペレーティング システムWindows OS
オペレーティング システムのバージョン10.0 64 Bit
修正されたバージョン3.3
ステータスWill Not Be Addressed

参考情報

This is due to data issues. The centerlines associated with the route with OID 4375 are not coincident in 3D (the Z values between the centerlines are different). When the junction point is added, a cartographic realignment is triggered and fails due to the Z values not being connected.

対処法

Snapping an Unknown/Unknown Asset Group Asset Type point to the line works successfully, and then changing this to Weld/Weld. The Snap geoprocessing tool also allows snapping the Weld/Weld or other points to the line.

再現の手順

不具合 ID: BUG-000164825