laptop and a wrench

不具合

Upstream traces return incorrect or misleading results

ArcGIS Pro
不具合 ID 番号 BUG-000172481
送信されましたNovember 21, 2024
最終更新日January 5, 2025
適用対象ArcGIS Pro
見つかったバージョン3.3
オペレーティング システムWindows OS
オペレーティング システムのバージョン10.0 64 Bit
ステータスAs Designed

参考情報

When running an upstream trace, if loops are encountered upstream from the starting point, these will be pulled into the result when Allow Indeterminate Flow is checked. In the provided scenario, the upstream trace encounters a line end which participates in junction junction connectivity associations with 3 fuse devices and another riser, creating a loop. Because Allow Indeterminate Flow is checked (enabled), the features within the loop are returned with the result, because we have no way to determine if the features are upstream or downstream of the starting point. Unchecking (disabling) Allow Indeterminate Flow with the trace returns the expected result and excludes the features from the upstream trace result.

対処法

Uncheck (disable) Allow Indeterminate Flow when running the upstream trace.