Tracing connected features in a Utility Network from a barrier with two terminals does not traverse the opposite terminal.

ArcGIS Pro
不具合 ID 番号 BUG-000165667
送信されましたMarch 6, 2024
最終更新日June 5, 2024
適用対象ArcGIS Pro
見つかったバージョン3.2.2
オペレーティング システムWindows OS
オペレーティング システムのバージョン10.0 64 Bit
ステータスAs Designed

参考情報

In this scenario, a Condition barrier is configured for both the IN and OUT terminals (Asset Group is equal to Indeterminate) on the device, whereas a Starting point is only present on the IN terminal. Ignore Starting Points at Barriers is honored properly in this case but does not apply to the OUT terminal which also has a barrier present. This is what led to the trace result reported.

対処法

Place a second starting point on the other terminal (so that both the IN and OUT terminals have starting points) and run the trace again with the Ignore Barriers at Starting Points parameter checked.