laptop and a wrench

不具合

The Vertical Coordinate System NAVD88 (height) (ftUS) switches the linear unit from feet to meters after running the Raster To TIN geoprocessing tool.

最後に公開された状態: December 6, 2021 ArcGIS Pro
不具合 ID 番号 BUG-000144402
送信されましたNovember 9, 2021
最終更新日September 16, 2025
適用対象ArcGIS Pro
見つかったバージョン2.8.3
オペレーティング システムWindows OS
オペレーティング システムのバージョン10.0
ステータスAs Designed

参考情報

After review by the development team, it was determined that the behavior is as designed. By default, the tool applies a z-factor when the input XY and Z units are different in order to make Z the same as XY. The z-factor parameter is set when selecting the raster (because XY are meters and Z is feet). To override the default behavior of the z unit conversion, reset the z factor to 1. When a z-factor other than 1 is applied, while the z units are properly changed, the VCS becomes a custom VCS and the WKID changes to 0. If desired, the user can manually reset this.

再現の手順

不具合 ID: BUG-000144402

ソフトウェア:

  • ArcGIS Pro

バグのステータスが変更されたときに通知を受け取る

Esri Support アプリのダウンロード

このトピックについてさらに調べる

ArcGIS エキスパートのサポートを受ける

テクニカル サポートへのお問い合わせ

Esri Support アプリのダウンロード

ダウンロード オプションに移動