The Gas Utility Network Configuration of the Cathodic network trace fails to pass through a cathodically traceable regulator device.

最後に公開された状態: July 11, 2022 ArcGIS Pro
不具合 ID 番号 BUG-000149307
送信されましたMay 17, 2022
最終更新日June 5, 2024
適用対象ArcGIS Pro
見つかったバージョン2.6.8
オペレーティング システムWindows OS
オペレーティング システムのバージョン10.0 64 Bit
ステータスKnown Limit

参考情報

Because the cathodic protection system is using the same features and connectivity as the water and gas commodity, it is limited by things like terminal configurations, associations, and terminal directions. The most common impact is when the test lead for a cathodic protection system is 'downstream' from a directional device like a pressure reducing valve resulting in the pressure reducing valve stopping the cathodic protection system.

対処法

Update the model to create a bonding junction on one of the sides of the dead zone and bridge the gap using a bonding wire.