laptop and a wrench

不具合

The error message, "Error 002136: The subnetwork field name already exists but does not match the expected field properties" is returned when running the Upgrade Dataset geoprocessing tool to upgrade a utility network.

最後に公開された状態: November 1, 2022 ArcGIS Pro
不具合 ID 番号 BUG-000152455
送信されましたSeptember 20, 2022
最終更新日June 5, 2024
適用対象ArcGIS Pro
見つかったバージョン2.9.4
オペレーティング システムWindows OS
オペレーティング システムのバージョン11.0 64 bit
ステータスAs Designed

参考情報

The SUPPORTINGSUBNETWORKNAME field applied to all applicable domain classes has properties that do not match those expected by the system (on creating a Utility Network or upgrading a dataset). When the SUPPORTINGSUBNETWORKNAME field is created, isRequired must be -1 which means True, and isEditable must be 0, which means False. In this data, isRequired is 0 and isEditable is -1, which caused the failure. The SUPPORTINGSUBNETWORKNAME field is not created until Utility Network Version 5. Removing these fields from the various classes allows the upgrade to be run successfully from Utility Network Version 4 to Version 5, or 6 (which then re-adds the fields in a supported manner).

対処法

  1. Take a full database backup as a safety net.
  2. Export Asset Package (with data included).
  3. Delete all data from the database.
  4. Stage Utility Network.
  5. Apply the asset package created in Step 2.