laptop and a wrench

不具合

The ConfigurationUtilityCL.exe process does not work with machines with names longer than 15 characters in ArcGIS Enterprise 10.8.1 or 10.9.

最後に公開された状態: July 10, 2021 Portal for ArcGIS
不具合 ID 番号 BUG-000140901
送信されましたJune 22, 2021
最終更新日July 19, 2023
適用対象Portal for ArcGIS
見つかったバージョン10.8.1
オペレーティング システムWindows OS
オペレーティング システムのバージョン2019 64 Bit
ステータスIn Review

対処法

Many environments require fully descriptive machine names which makes shortening the name not feasible.

For ArcGIS Enterprise upgrades from 10.8.1 to 10.9.1 and where the NetBIOS name does not match the hostname on Data Store machines:

  1. Note the existing server URL for the data store item. For example, datastore-machine.domain.local:6443
  2. Create a backup using the ArcGIS Data Store utility.
    1. backupdatastore.bat
  3. Upgrade the ArcGIS Enterprise software to 10.9.1.
  4. Restore the backed up data store using the ArcGIS Data Store utility.
    1. restoredatastore.bat --store relational --target most-recent --bound true --server-url datastore-machine.domain.local:6443 --server-admin siteadmin --server-password secretPassword --data-dir d:\arcgisdatastore --source-loc d:\arcgisdatastore\backup