laptop and a wrench

不具合

The cluster tolerance parameter for the Planarize tool is not respected when a feature class is in a geographic coordinate system.

最後に公開された状態: January 5, 2021 ArcGIS Pro
不具合 ID 番号 BUG-000135935
送信されましたDecember 8, 2020
最終更新日July 10, 2025
適用対象ArcGIS Pro
見つかったバージョン2.6.3
オペレーティング システムWindows OS
オペレーティング システムのバージョン10.0 64 Bit
修正されたバージョン2.7
ステータスFixed

対処法

  • Use a projected coordinate system (PCS).
  • Perform the following workaround if the user must work in a geographic coordinate system editing environment:
  1. Set the XY tolerance when creating the feature class. For example, 0.000106177 is about 10m, depending on the locale.
  2. Use the Planarize tool, and use the value '0' for the cluster tolerance parameter. This can bring in the XY tolerance from the feature class to be used in the tool, and provide an accurate cluster distance value for the latitude. Refer to ​​​​​​​https://pro.arcgis.com/en/pro-app/tool-reference/environment-settings/xy-tolerance.htm for more information.

再現の手順

不具合 ID: BUG-000135935