laptop and a wrench

不具合

Temperature conversions performed on mosaic datasets containing GRIB rasters in Kelvin degrees do not successfully convert pixel values when using Mosaic Processing Templates in ArcGIS Pro.

最後に公開された状態: April 6, 2018 ArcGIS Pro
不具合 ID 番号 BUG-000107772
送信されましたSeptember 1, 2017
最終更新日June 5, 2024
適用対象ArcGIS Pro
見つかったバージョン2.0.1
ステータスNon-Reproducible

参考情報

The issue cannot be reproduced in Pro 2.1 release.

対処法

1. In the Catalog pane, right-click the mosaic dataset > Edit Mosaic Dataset Functions.2. Click the Analysis tab > Raster Functions.3. In the Raster Functions tab, expand Conversion and drag and drop Unit Conversion into the raster function window. Connect the Mosaic box to the Unit Conversion box. 4. Double-click the Unit Conversion box and set From Unit to Kelvin and to Unit to Celsius. 5. Validate and run the function. 6. Click around the mosaic. Note that the pixel values in the pop-up are correctly in Celsius.