laptop and a wrench

不具合

Slow performance when validating a utility network topology to a small extent.

最後に公開された状態: August 25, 2022 ArcGIS Pro
不具合 ID 番号 BUG-000149769
送信されましたJune 6, 2022
最終更新日June 5, 2024
適用対象ArcGIS Pro
見つかったバージョン2.9.2
オペレーティング システムWindows OS
オペレーティング システムのバージョン10.0 64 Bit
修正されたバージョン3.1
ステータスWill Not Be Addressed

参考情報

Validate performance is related to the subnetwork traces being run during validation. Trace times are high because the subnetworks traced are large. In the test case presented, 3 large traces are run during the validation with the majority of the time spent querying the adjacent junctions and edges for each junction as well as checking whether each element encountered is a condition barrier. The time to trace all of these elements falls in line with expectations for the number of elements processed per second. The underlying issue is related to the subnetwork definition for the tiers. After updating the subnetwork definition to stop on closed device status, validates are not taking more than a couple of seconds. A possible course of action is to set 'Manage IsDirty = false' for all tiers. This enables subnetwork traces to be run but does not require this to be done on validation. This speeds up validations until the data is in a clean enough state to turn it back on.

再現の手順

不具合 ID: BUG-000149769

ソフトウェア:

  • ArcGIS Pro

バグのステータスが変更されたときに通知を受け取る

Esri Support アプリのダウンロード

このトピックについてさらに調べる

ArcGIS エキスパートのサポートを受ける

テクニカル サポートへのお問い合わせ

Esri Support アプリのダウンロード

ダウンロード オプションに移動