laptop and a wrench

不具合

Running the Calculate Field tool from a Double field to a Long field returns warnings: "Warning 001156: Failed on input OID <value>; could not write value '<value>' to output field <value>" and "Warning 000595: <value> contains the full list of records not able to be processed."

ArcGIS Pro
不具合 ID 番号 BUG-000159689
送信されましたJuly 6, 2023
最終更新日March 20, 2025
適用対象ArcGIS Pro
見つかったバージョン3.1
オペレーティング システムWindows OS
オペレーティング システムのバージョン10.0 64 Bit
ステータスAs Designed

参考情報

There are two different situations described. For the double-to-long calculation, the maximum value a long integer field can accept is 2147483647. The first 5 numbers in the table are beneath that threshold, so they work, but the numbers with an area code of 714 exceed the maximum value a long field can accept. In the other case, it is not possible to move values from a text field that are structured as a phone number into a numeric field. Alternatively, convert purely numeric values in a text field to a numeric field so the tool does not block this.

再現の手順

不具合 ID: BUG-000159689

ソフトウェア:

  • ArcGIS Pro

バグのステータスが変更されたときに通知を受け取る