In ArcGIS Data Interoperability, when integrating a JavaScript Object Notation (JSON) file with 64-bit signed integer values as well as 64-bit unsigned integer numbers, the 64-bit signed integers appear correctly, but the 64-bit unsigned integers are converted to negative numbers.

最後に公開された状態: March 20, 2023 ArcGIS Pro
不具合 ID 番号 BUG-000156639
送信されましたMarch 15, 2023
最終更新日May 15, 2025
適用対象ArcGIS Pro
見つかったバージョン3.0.4
オペレーティング システムWindows OS
オペレーティング システムのバージョン10.0 64 Bit
ステータスKnown Limit

参考情報

The geodatabase has a known range limit of -2 ^ 53 minus 1 and 2 ^ 53 minus 1. While the Workbench app can read big integer values up to 2 ^ 64, the values cannot be written in the geodatabase as destination formats due to these known limits. Refer to this documentation https://pro.arcgis.com/en/pro-app/latest/help/data/geodatabases/overview/arcgis-field-data-types.htm#ESRI_SECTION2_8BF2454C879941258DC44AF6BB31F386 for more information.

対処法

If the user wants to keep the values from the source format to the geodatabase, the workaround is to convert the big integer values to string.