Fme.exe processes do not close after an Feature Manipulation Engine (FME) task ends.

最後に公開された状態: June 23, 2022 ArcGIS Pro
不具合 ID 番号 BUG-000149798
送信されましたJune 7, 2022
最終更新日July 23, 2025
適用対象ArcGIS Pro
見つかったバージョンN/A
オペレーティング システムWindows OS
オペレーティング システムのバージョン10.0 64 Bit
ステータスIn Product Plan

参考情報

A memory leak happens during the author-test workspace lifecycle, freezing the run of the translation. It usually happens when the Feature Cache is enabled. There is no exact reproducible step identified yet except for this known behavior.

対処法

This is a known issue which is not easily reproducible. The workaround is to kill the duplicates of fmeobjectworker.exe process in the Task Manager and Details pane. Killing the correct fmeworkerobject.exe process leak frees up the memory so the translation will often run again. Save the workspace before attempting to kill any process. Another suggestion, is to restart the workbench app and use feature caching sparingly, especially when the workspace is in production. This would be counter productive for authoring however it is believed there is a link between feature caching and this bug.

Refer to this documentation: https://community.esri.com/t5/arcgis-data-interoperability-documents/workbench-app-is-frozen-in-quot-starting/ta-p/1632171 for more information.