laptop and a wrench

不具合

Coordinates for a MicroStation DGN file created with U. S. survey foot units are read in ArcMap as international foot units.

最後に公開された状態: August 31, 2014 ArcGIS for Desktop
不具合 ID 番号 NIM094881
送信されましたSeptember 13, 2013
最終更新日June 5, 2024
適用対象ArcGIS for Desktop
見つかったバージョン10.0
ステータスNon-Reproducible

参考情報

No Public Explanation

対処法

The coordinate system for the microstation file test.DGN has no geographic coordinate system assigned.To add a geographic coordinate system to this drawing in Microstation do the following:1. Click on the Tool menu2. Select the Geographic tool bar3. Choose Select a Coordinate System4. You will notice that currently None is selected5. Navigate to the Coordinate System library and choose the appropriate coordinate system6. Once the proper coordinate system is assigned close Microstation and add the DGN file to ArcMap 7. Add the above shapefile8. Notice that the drawings now align

再現の手順

不具合 ID: NIM094881

ソフトウェア:

  • ArcGIS for Desktop

バグのステータスが変更されたときに通知を受け取る

Esri Support アプリのダウンロード

このトピックについてさらに調べる

ArcGIS エキスパートのサポートを受ける

テクニカル サポートへのお問い合わせ

Esri Support アプリのダウンロード

ダウンロード オプションに移動