laptop and a wrench

不具合

All errors removed from Build Errors table after one turn feature is edited (though not corrected) and the network dataset is rebuilt.

最後に公開された状態: August 25, 2014 ArcGIS for Desktop
不具合 ID 番号 NIM061475
送信されましたSeptember 23, 2010
最終更新日June 5, 2024
適用対象ArcGIS for Desktop
見つかったバージョン10.0
オペレーティング システムWindows OS
オペレーティング システムのバージョンXP
ステータスWill Not Be Addressed

参考情報

We apologize that we were unable to address this issue within the current product support cycle. If the issue continues to affect your work in a supported release, please contact Technical Support.

対処法

If you drop the turn feature class from the network and then readd the turn feature class and rebuild the network dataset (to do this Right click on the network dataset in ArcCatalog/Properties/Turns Tab and remove Restricted Turns, then re-add Restricted Turns, click OK and then rebuild network ), all the errors show up again in the BuildErrors.txt, except for the one turn feature that was edited (but not corrected).

再現の手順

不具合 ID: NIM061475