français
Continue in the app
Numéro de bogue BUG-000124785
Envoyé Aug 26, 2019
Modified Apr 25, 2022
Gravité Medium
S’applique à Portal for ArcGIS
Version trouvée 10.6.1
Langage de programmation N/D
Plateforme serveur Windows OS 2016 64 Bit
Plateforme client Windows OS 2016 64 Bit
Base de données N/D
Paramètre régional N/D
Statut Unknown Text - Bugs/Fixed
Learn more
Version corrigée 10.8
Résolu par le fournisseur N/A

Bogue BUG-000124785

Synopsis

After failover, if an incremental backup is requested but a full backup has not been run, run a full backup instead of an incremental.


Informations supplémentaires

N/D


Autre solution

There are 2 workarounds:

  • Set the backup location to a shared location. Since both data store machines can access the backup location for the data store that stores incremental snapshots, they are able to avoid issues when an incremental backup is requested after a failover.